Exhaust flow directed up and away from roof minimum 40 above roof electrical and roof access requirements 1.
10 away from property line exhaust in roof.
Exhaust vents must not be allowed to be obscured or hidden by vegetation.
5 1 5 roof grade with snow accumulation.
And directed away as much as possible from residential uses within 50 feet 15 240 mm of the vent in some locations.
Exhaust outlets extending to the roof shall extend 3 feet 914 mm above the roof surface.
Air exhaust openings shall terminate not less than 3 feet 914 mm from property lines.
3 feet 914 mm from operable openings into buildings for.
The current chimney heat duct that they are using fills our home with smoke.
Ducts conveying explosive or flammable vapors fumes or dusts shall terminate not less than 30 feet 9144 mm from a property line 10 feet 3048 mm from openings into the building 6 feet 1829 mm from exterior walls or roofs 30 feet 9144 mm from combustible walls or openings into the building that are in the direction of the exhaust discharge and 10 feet 3048 mm above adjoining grade.
10 from property lines 3.
10 3 private washrooms exhaust.
Thru the roof be installed from the property line july 2.
3 feet 914 mm from property lines.
1 0 30 property line.
The exhaust shall be directed away from the building.
The termination of chimneys or vents equipped with power exhausters shall be located a minimum of 10 feet 3048 mm from the lot line or from adjacent buildings.
10 3 private road driveway 5 1 5 building exhaust clean 5 1 5 automobile parking area.
Horizontal terminations shall comply with the following requirements.
Exhaust vents must be protected against rain and equipped with back flow prevention features e g flap dampers.
3 feet 914 mm from operable and nonoperable openings into the building and 10 feet 3048 mm from mechanical air intakes except where the opening is located 3 feet 914 mm above the air intake.
Of stretched string distance from known contamination sources e g stack vent exhaust vehicles not exiting the roof and 3 ft.
Above grade or roof deck.
The property line is only about 24 inches away from the side of their house and about 10 feet from the side of our home.
7 7 2 inlet is 2 ft.
Distance from sources exiting the roof.
3 above any air intake within 10 2.
15 5 public washroom exhaust.
7 7 3 inlet is provided with rodent insect screen with 0 5 inch mesh.
I presume you re talking about an exhaust vent for some sort of fuel fired.
Exhaust system shall operate whenever cooking equipment is turned on cmc 514 1 rooftop terminations per cmc 510 9 1 1.