Valleys will be open so flash them before hand with metal or two layers of roll roofing the first an 18 inch wide strip and the second 36 inches wide.
2 layers roll roofing.
How to install roll roofing on low slope roofs.
Attach drip edge along the edge of the roof with roofing cement.
Check the sheathing for any nails or screws that may be.
The top membrane sheet to a torch down roofing system is a smooth cap sheet.
As mentioned above place the first 6 inches 15 cm of the second layer on top of the first layer.
Assuming your roofing contractor is using standard 36 wide 15 roofing felt double coverage means that each layer of felt put down across the roof laps 19 over the upper half of the previous course.
Once the cement is spread across the roof it s time to place the second layer down.
Otherwise the safest minimum pitch for rolled roofing is 2 inches of decline per 12 inches of horizontal direction 2 12 pitch.
Owens corning deckseal sa sbs cap 39 375 ft w x 32 833 ft l 100 sq ft shasta white roll roofing.
Clean the roof with a broom to remove any debris.
Nail along one edge first spacing nails inch in from the edge and 6 inches apart.
There are some advantages to roofing over existing shingles says dale richards owner of richards roofing in troy michigan.
For extra durability you may install roll roofing in two layers.
It also helps if you first install a layer of roofing felt.
In a two layer torch down roof the system is complete at this point.
Then nail the opposite edge.
When the two layers are pressed together they form a seal.
The homeowner will have two layers of shingles protecting the roof and the home is less likely to have ice dams he says.
Install the first strip upside down.
Get your trowel and another scoop of cement and apply it on the roof below the second chalk line.
For many years it was acceptable to put even the third layer.
So anywhere along the gable end that you can see the felt you ll see two layers.
As it is rolled out the roofing professional will use a torch to heat the bottom of the cap to the top of the base sheet.
Richards also estimates that the homeowner saves at least 1 000 in costs associated with removing and properly disposing of the existing shingles.
Extend the front edge of the drip edge so it runs off the roof and into the.
The first course starts with an extra 1 2 wide run.
The strips should always be horizontal.
On most flat roofs such as epdm tpo or modified it is perfectly acceptable to two layers of roofing.
If your roof pitch declines up to 1 inch vertically for every 12 inches horizontally 1 12 pitch it is a good candidate for rolled roofing as long as you use the concealed nail method of fastening.
Steep sloped roof products such as tile slate metal and shakes only allow one layer.